| Radial Leaded PPTC - FRX
Series
※
RoHS Compliant
/
(Lead
Free) Available |
| |
|
Application: |
Wide variety of electronic equipment |
| Product Features: |
Low hold current, Solid state, Radial-leaded product ideal for up
to 60V |
| Operation Current: |
50mA ~ 3.75A |
| Maximum Voltage: |
60VDC |
| Temperature Range: |
-40°C to 85°C |
| Agency Recognition: |
UL(E211981)
C_UL(E211981)
TÜV (R3-50004084) |
|
| |
|
| |
|
|
| |
|
|
| |
Part
Number |
Hold
Current |
Trip
Current |
Max.Time
to Trip
|
Maximum
Current
|
Rated
Voltage
|
Typical
Power
|
Resistance |
| RMIN |
R1MAX |
| IH,
A |
IT,
A |
at 5xIH, S |
IMAX,
A |
VMAX,Vdc |
Pd, W |
ohms |
ohms |
FRX005-60F |
0.05 |
0.10 |
5.00 |
40 |
60 |
0.26 |
7.30 |
20.0 |
FRX010-60F |
0.10 |
0.20 |
4.00 |
40 |
60 |
0.38 |
2.50 |
7.50 |
FRX017-60F |
0.17 |
0.34 |
3.00 |
40 |
60 |
0.48 |
2.00 |
7.00 |
FRX020-60F |
0.20 |
0.40 |
2.20 |
40 |
60 |
0.41 |
1.83 |
4.40 |
FRX025-60F |
0.25 |
0.50 |
2.50 |
40 |
60 |
0.45 |
1.25 |
3.00 |
FRX030-60F |
0.30 |
0.60 |
3.00 |
40 |
60 |
0.49 |
0.88 |
2.10 |
FRX040-60F |
0.40 |
0.80 |
3.80 |
40 |
60 |
0.56 |
0.55 |
1.29 |
FRX050-60F |
0.50 |
1.00 |
4.00 |
40 |
60 |
0.77 |
0.50 |
1.17 |
FRX065-60F |
0.65 |
1.30 |
5.30 |
40 |
60 |
0.88 |
0.31 |
0.72 |
FRX075-60F |
0.75 |
1.50 |
6.30 |
40 |
60 |
0.92 |
0.25 |
0.60 |
| FRX090-60F |
0.90 |
1.80 |
7.20 |
40 |
60 |
0.99 |
0.20 |
0.47 |
FRX110-60F |
1.10 |
2.20 |
8.20 |
40 |
60 |
1.50 |
0.15 |
0.38 |
FRX135-60F |
1.35 |
2.70 |
9.60 |
40 |
60 |
1.70 |
0.12 |
0.30 |
FRX160-60F |
1.60 |
3.20 |
11.4 |
40 |
60 |
1.90 |
0.09 |
0.22 |
FRX185-60F |
1.85 |
3.70 |
12.6 |
40 |
60 |
2.10 |
0.08 |
0.19 |
FRX250-60F |
2.50 |
5.00 |
15.6 |
40 |
60 |
2.50 |
0.05 |
0.13 |
FRX300-60F |
3.00 |
6.00 |
19.8 |
40 |
60 |
2.80 |
0.04 |
0.10 |
FRX375-60F |
3.75 |
7.50 |
24.0 |
40 |
60 |
3.20 |
0.03 |
0.08 |
|
| |
IH=Hold current-maximum
current at which the device will not trip at 23°C still air.
IT=Trip current-minimum current at which the device
will always trip at 23°C still air.
V MAX=Maximum voltage device can withstand without
damage at its rated current.
I MAX= Maximum fault current device can withstand
without damage at rated voltage (V max).
Pd=Typical power dissipated from device when in the tripped state in 23°C
still air environment.
RMIN=Minimum device resistance at 23°C.
R1MAX=Maximum device resistance at 23°C, 1
hour after tripping .
Physical specifications:
Lead material: FRX005~FRX090 Tin plated copper, 24 AWG. FRX110~FRX375 Tin
plated copper, 20 AWG.
Soldering characteristics: MIL-STD-202, Method 208E.
Insulating coating:Flame retardant epoxy, meet UL-94V-0 requirement.*NOTE:UL,
C-UL and
TÜV are only applied for FRX010-60F~FRX375-60F |
| |
 |
 |
 |
FRX 005-60 ~ FRX 090-60
Lead Size :24AWG, Ø 0.51 mm Diameter |
FRX FRX 110-60 ~ FRX 375-60
Lead Size : 20AWG, Ø 0.81 mm Diameter |
| Part
Number |
A |
B |
C |
D |
E |
F |
| Maximum |
Maximum |
Typical |
Minimum |
Maximum |
Typical |
| FRX005-60F |
7.4 |
12.7 |
5.1 |
7.6 |
3.1 |
1.1 |
| FRX010-60F |
7.4 |
12.7 |
5.1 |
7.6 |
3.1 |
1.1 |
| FRX017-60F |
7.4 |
12.7 |
5.1 |
7.6 |
3.1 |
1.1 |
| FRX020-60F |
7.4 |
12.7 |
5.1 |
7.6 |
3.1 |
1.1 |
| FRX025-60F |
7.4 |
12.7 |
5.1 |
7.6 |
3.1 |
1.1 |
| FRX030-60F |
7.4 |
13.0 |
5.1 |
7.6 |
3.1 |
1.1 |
| FRX040-60F |
7.6 |
13.5 |
5.1 |
7.6 |
3.1 |
1.1 |
| FRX050-60F |
7.9 |
13.7 |
5.1 |
7.6 |
3.1 |
1.1 |
| FRX065-60F |
9.7 |
14.5 |
5.1 |
7.6 |
3.1 |
1.1 |
| FRX075-60F |
10.4 |
15.2 |
5.1 |
7.6 |
3.1 |
1.1 |
| FRX090-60F |
11.7 |
15.8 |
5.1 |
7.6 |
3.1 |
1.1 |
| FRX110-60F |
13.0 |
18.0 |
5.1 |
7.6 |
3.1 |
1.4 |
| FRX135-60F |
14.5 |
19.6 |
5.1 |
7.6 |
3.1 |
1.4 |
| FRX160-60F |
16.3 |
21.3 |
5.1 |
7.6 |
3.1 |
1.4 |
| FRX185-60F |
17.8 |
22.9 |
5.1 |
7.6 |
3.1 |
1.4 |
| FRX250-60F |
21.3 |
26.4 |
10.2 |
7.6 |
3.1 |
1.4 |
| FRX300-60F |
24.9 |
30.0 |
10.2 |
7.6 |
3.1 |
1.4 |
| FRX375-60F |
28.5 |
33.5 |
10.2 |
7.6 |
3.1 |
1.4 |
|
|
| |
 |
| |
|
| |
 |
| |
A = FRX005-60F
B = FRX010-60F
C = FRX017-60F
D = FRX020-60F
E = FRX025-60F
F = FRX030-60F
G = FRX040-60F
H = FRX050-60F
I = FRX065-60F
J = FRX075-60F
K= FRX090-60F
L = FRX110-60F
M = FRX135-60F
N = FRX160-60F
O = FRX185-60F
P = FRX250-60F
Q = FRX300-60F
R = FRX375-60F |
 |
|
| |


|
| |
 |
| |
| P/N |
Pcs
/Bag |
Reel/Tape |
| FRX005-60F |
500 |
3K |
| FRX010-60F |
500 |
3K |
| FRX017-60F |
500 |
3K |
| FRX020-60F |
500 |
3K |
| FRX025-60F |
500 |
3K |
| FRX030-60F |
500 |
3K |
| FRX040-60F |
500 |
3K |
| FRX050-60F |
500 |
3K |
| FRX065-60F |
300 |
3K |
|
|
| P/N |
Pcs
/Bag |
Reel/Tape |
| FRX075-60F |
300 |
3K |
| FRX090-60F |
300 |
3K |
| FRX110-60F |
300 |
1.5K |
| FRX135-60F |
200 |
1.5K |
| FRX160-60F |
200 |
1.5K |
| FRX185-60F |
200 |
1.5K |
| FRX250-60F |
100 |
1K |
| FRX300-60F |
100 |
1K |
| FRX375-60F |
100 |
1K |
|
|
| |
| Warning: |
- Operation beyond the specified maximum ratings or improper use
may result in damage and possible electrical arcing and/or flame.
- PPTC device are intended for occasional overcurrent protection.
Application for repeated overcurrent condition and/or prolonged
trip are not anticipated.
- Avoid contact of PPTC device with chemical solvent. Prolonged
contact will damage the device performance.
|
| |
All the specifications are subject to change
without previous notice.
|